Street view of 1344 S Kolin Ave, Chicago, IL 60623

1344 S Kolin Ave
Chicago, IL 60623 · North Lawndale

Small default

Nearby Transit


Nearby Schools

School data provided by GreatSchools

1344 S Kolin Ave, Chicago, IL 60623

Apartment in North Lawndale

1344 S Kolin Ave is a apartment located at 1344 S Kolin Ave, Chicago, IL 60623, in the area is commonly known as North Lawndale.

this building is 0 stories tall and contains apartments. It is owned by (unknown).

Owner & Management

Contacts
None listed

Building Facts

Year Built
Year Renovated
unspecified
Style
Total Apartments
apartments ( per floor)
Total Floors
Owner
unspecified
Management
unknown
Problems
78 issues found
Building Class
unspecified
Built Area
0 ft2
Lot Area
0 ft2 ( × )
FAR
0
Zoning District
unspecified

Closed Sales

Date Unit Price Details

Complaints, Violations & Permits

Write a Review

Summary
Violation VACANT BUILDING - REGISTER

Status last updated on Apartable at 2011-08-12 00:00:00 UTC.
Permit PERMIT - EASY PERMIT PROCESS

Status last updated on Apartable at 2014-08-04 16:43:25 UTC.
Violation INSTALL COVERS

BASEMENT DANGEROUS AND HAZARDOUS\n\nInstall cover on outlet or junction box. (18-27-370.25)

Status last updated on Apartable at 2009-12-01 00:00:00 UTC.
Violation REMOVE EXPOSED CABLE

ROMEX IN BASEMENT\n\nRemove exposed non-metallic cable. (18-27-336.3, 18-27-336.4, 18-27-336.5)

Status last updated on Apartable at 2009-12-01 00:00:00 UTC.
Violation CLOSE BOX OPENINGS

PANEL COVERS BASEMENT DANGEROUS AND HAZARDOUS\n\nClose unused opening in electrical box or cabinet. (18-27-373.4)

Status last updated on Apartable at 2009-12-01 00:00:00 UTC.
Violation DEFECTIVE OUTLETS

1SR FLOOR THROUGHOUT DEFECTIVE AND PAINTED\n\nReplace broken, inoperable, or painted over receptacle or switch. (18-27-200.1, 18-27-200.10(b))

Status last updated on Apartable at 2009-12-01 00:00:00 UTC.
Violation DEFECTIVE FIXTURES

1ST FLOOR EXTERIOR LIGHT MISSING EXPOSED WIRES DANGEROUS AND HAZARDOUS\n\nReplace defective light fixture. (18-27-410.22, 18-27-410.23, 18-27-410.24, 18-27-240.27, 18-27-410.36, 18-27-410.37, 18-27-410.38, 18-27-410.39)

Status last updated on Apartable at 2009-12-01 00:00:00 UTC.
Violation CIRCUIT ONE UNIT ONLY

Status last updated on Apartable at 2009-12-01 00:00:00 UTC.
Violation EXPOSED WIRING FIXTURES

1ST FLOOR KITCHEN AND BASEMENT\n\nRemove exposed wiring at light fixture. (18-27-410.24, 18-27-410.28)

Status last updated on Apartable at 2009-12-01 00:00:00 UTC.
Violation EXPOSED WIRING

BASEMENT PANELS DANGEROUS AND HAZARDOUS\n\nRemove exposed wiring. (18-27-300.4)

Status last updated on Apartable at 2009-12-01 00:00:00 UTC.
Violation TENANT ACCESS TO SERVICE

Status last updated on Apartable at 2009-12-01 00:00:00 UTC.
Violation UNAPPROVED HEATING DEVICE

USING COOKING STOVE AS HEATING DEVICE.\n\nStop using cooking or water heating device as heating device. (13-196-400)

Status last updated on Apartable at 2009-01-15 00:00:00 UTC.
Violation SAFE WORKING CONDITIONS

FURNACE OUT OF SERVICE AT TIME OF INSPECTION.\n\nProvide and maintain every facility, piece of equipment, or utility in safe and sound working condition. (13-196-400, 13-196-440)

Status last updated on Apartable at 2009-01-15 00:00:00 UTC.
Violation SUPPLY HOT WTR MIN TEMP 120DEG

HOT WATER SUPPLIED AT ONLY 87 F.\n\nSupply adequate hot water with minimum temperature of 120 degrees F. (13-196-430)

Status last updated on Apartable at 2009-01-15 00:00:00 UTC.
Violation REPAIR DOOR, INT.

NON VENTED DOOR AT FURNACE ROOM 3RD FL.\n\nRepair or replace defective door. (13-196-550)

Status last updated on Apartable at 2008-05-08 00:00:00 UTC.
Violation REPAIR INTERIOR WALLS/CEILING

SAGGING CEILING KITCHEN 3RD, BEDROOM CEILING CRACK\n\nFailed to maintain interior walls and ceilings free from holes or cracks. (13-19-540(c))

Status last updated on Apartable at 2008-05-08 00:00:00 UTC.
Violation SUPPORT FIXTURES

HANGING LIGHT FIXTURE KITCHEN & BEDROOM CEILINGS 3RD FL.\n\nSupport loose light fixture. (18-27-410.15, 18-27-415.16)

Status last updated on Apartable at 2008-05-08 00:00:00 UTC.
Violation OBSTRUCTIONS IN EXIT WAY

FRONT AND REAR YARD FENCES PADLOCKED, BROKEN GLASS AT FRONT ENTRANCES DOOR FIRST FLOOR.\n\nFailed to remove obstruction from exitway that hampers travel and evacuation. (13-160-070, 13-196-080)

Status last updated on Apartable at 2008-05-08 00:00:00 UTC.
Violation POST OWNER/MANAGERS NAME/#

MISSING MANAGEMENT SIGN\n\nPost name, address, and telephone of owner, owner's agent for managing, controlling or collecting rents, and any other person managing or controlling building conspicuously where accessible or visible to public way. (13-12-030)

Status last updated on Apartable at 2008-05-08 00:00:00 UTC.
Violation INSTALL SMOKE DETECTORS

MISSING DETECTOR FRONT STAIRWAY\n\nInstall and maintain approved smoke detectors. (13-196-100 thru 13-196-160) Install a smoke detector in every dwelling unit. Install one on any living level with a habitable room or unenclosed heating plant, on the uppermost ceiling of enclosed porch stairwell, and within 15 feet of every sleeping room. Be sure the detector is at least 4 inches from the wall, 4 to 12 inches from the ceiling, and not above door or window.

Status last updated on Apartable at 2008-05-08 00:00:00 UTC.
Violation REPAIR PORCH SYSTEM

REAR PORCH LOOSE STRINGER AND TREAD 2ND TO 3RD LOOSE RAILS 1ST TO 2ND AND MISSING JOIST HANGERS OBTAIN PERMIT NO PLANS NEEDED.\n\nFailed to repair or replace defective or missing members of porch system. (13-196-570, 13-196-641)

Status last updated on Apartable at 2008-05-08 00:00:00 UTC.
Violation REPAIR ROOF

LEAKING CEILING KITCHEN 3RD FL.\n\nFailed to maintain roof in sound condition and repair, watertight and free from defects. (13-196-530, 13-196-530(c) and 13-196-641)

Status last updated on Apartable at 2008-05-08 00:00:00 UTC.
Violation PROVIDE DEADLOCK FOR ENTRANCE

MISSING DEAD BOLT LOCK 3RD FL ENTRY DOOR FRONT\n\nFailed to provide and install building entrance door with deadlock latch with at least a 1/2 inch latch bolt projection for multi-unit residential buildings without an attendant being continuously on duty. (13-164-040)

Status last updated on Apartable at 2008-05-13 00:00:00 UTC.
Violation INSTALL DOOR VIEWING DEVICE

MISSING VIEWING DEVICE 3RD FL FRONT ENTRY DOOR.\n\nFailed to install door viewing device at the entrance door of a dwelling unit. (13-164-030)

Status last updated on Apartable at 2008-05-13 00:00:00 UTC.
Violation RATS

RATS 3RD FLOOR APT.\n\nRid premises of rodents and seal rodent holes. (13-196-530 D, 13-196-540 A, 13-196-630 C)

Status last updated on Apartable at 2008-05-13 00:00:00 UTC.
Violation OBSTRUCTIONS IN EXIT WAY

NORTH, SOUTH ELEVATIONS SIDE GATES ARE CHAINED AND PADLOCKED\n\nFailed to remove obstruction from exitway that hampers travel and evacuation. (13-160-070, 13-196-080)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPAIR EXTERIOR DOOR SILL

EAST ELEVATION GAPS AT FRONT ENTRY DOOR THRESHOLD\n\nFailed to maintain exterior door sill in sound condition and repair. (13-196-550, 13-196-641)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation ADDITIONAL EXIT

BUILDING ONLY ONE MODE OF ENTRY AND EGRESS NORTH AND SOUTH GATES ARE LOCKED PREVENTING EXIT\n\nProvide additional means of egress. (13-196-050, 13-160-050)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation PARAPET

SOUTH ELEVATION LOOSE MORTAR AT PARAPET WALL\n\nFailed to maintain parapet wall in good repair and free from cracks and defects. (13-196-530 and 13-196-641)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation CHIMNEY CAPPING

SOUTH ELEVATION CHIMNEY CAP MISSING\n\nCap masonry chimney with non-combustible, water proof materials. (13-152-250 B, 13-152-240, 13-196-590)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPAIR CORNICE

EAST ELEVATION PEELING PAINT AT CORNICES\n\nFailed to maintain cornice in good repair and free from cracks and defects. (13-196-530(e), 13-196-641)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation INSTALL DOOR VIEWING DEVICE

ALL APARTMENTS VIEWING DEVICE MISSING AT FRONT ENTRY DOORS\n\nFailed to install door viewing device at the entrance door of a dwelling unit. (13-164-030)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPAIR LINTELS

EAST ELEVATION 2ND, 3RD FLOORS LINTELS ARE RUSTING\n\nFailed to maintain lintel in good repair and free from cracks and defects. (13-196-530(e), 13-196-641)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation ARRANGE PREMISE INSPECTION

NO RESPONSE BASEMENT UNIVERIFED DETECTORS\n\nArrange for inspection of premises. (13-12-100)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPAIR EXTERIOR DOOR

EAST ELEVATION FRONT ENTRY DOOR SIDE PANEL IS CRACKED PLEXIGLASS USED INSTEAD OF GLASS (TEMPERED)\n\nFailed to maintain exterior door in sound condition and repair. (13-196-550(d) and (e), 13-196-641)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation ROACHES

3RD FLOOR EVIDENCE OF ROACHES\n\nExterminate roaches and keep dwelling insect-free. (13-196-630 C)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation INSTALL DEAD BOLT LOCK

ALL APARTMENTS DEADBOLT LOCKS MISSING AT ALL FRONT ENTRY DOORS\n\nFailed to install dead bolt lock, with at least one inch saw resistant bolt projection or with rim mounted deadbolt or vertical drop-bolt lock of equivalent security, at the entrance door of a dwelling unit. (13-164-030)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPAIR OR REPLACE

3RD FLOOR APARTMENT BATHROOM VANITY CABINET AND SINK ARE NOT SECURED TO WALL LOOSE\n\nRepair or replace

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation WINDOW REPAIR FOR AIR SEEPAGE

3RD FLOOR APARTMENT GAPS AND CRACKS AROUND WINDOW FRAMES DRAFTY WINDOWS\n\nFailed to maintain windows in relation to the adjacent wall construction as to completely exclude rain and substantially exclude wind from entering the premises. (13-196-550(f))

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPAIR FLOOR

3RD FLOOR APARTMENT BATHROOM CRAKED TILES FURNACE ROOM PLYWOOD USED AS FINISH FLOOR\n\nFailed to maintain floor free from holes and wide cracks and free from loose, warped, protruding or rotting floor boards. (13-196-540(a) and (b))

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation CARB MONOX DETECT IN RESID

1ST FLOOR APARTMENT CARBON MONOXIDE DETECTOR IS MISSING\n\nInstall carbon monoxide detector within 40 feet of every sleeping room in residential structure. (13-64-190, 13-64-210) A carbon monoxide detector is needed whenever there is a heating appliance on the premises that burns fossil fuel such as gas, oil, or coal, or air that is circulated through a heat exchanger. Install according to manufacturer instructions. A hard wired model requires an electrical wiring permit. In a single family residence, be sure the detector is on or below the lowest floor with a place to sleep. In a multiple dwelling residence heated by a boiler, install a detector in the same room as the boiler. Otherwise, each apartment follows single family guidelines. The owner is responsible for installation and written instructions, the tenant for testing, maintenance, and batteries.

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation INT WALL/CEILING CHIP PLASTER

INTERIOR STAIRWELL 2ND FLOOR CRACKS IN STAIR SOFFIT WALLS NEAR WINDOW\n\nFailed to maintain interior ceilings and walls reasonably smooth, clean and tight and free from chipped or loose plaster or structural material. (13-196-540(d) and (e))

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation SUPPORT FIXTURES

INTERIOR STAIRWELL 2ND FLOOR CEILING FIXTURE IS HANGING\n\nSupport loose light fixture. (18-27-410.15, 18-27-415.16)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPAIR/REPLACE SMOKE DETECTORS

3RD FLOOR APARTMENT SMOKE DETECTOR IS OUT SERVICE; WITH LOW BATTERY\n\nRepair or replace defective or out of service smoke detectors and operate continuously. (13-196-130, 13-196-140)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation FOUNDATION FOR FURNACE/BOILER

3RD FLOOR APARTMENT FURNCE SITS DIRECTLY ON PLYWOOD FLOOR\n\nFailed to install foundation under floor furnace or boiler. (18-28-910.3, 18-28-1004.4, 18-28-1004.5)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation CHIMNEY HEIGHT

SOUTH ELEVATION CHIMNEY NOTEEXTENDED 24 ABOVE ROOF LINE\n\nRebuild chimney to appropriate height. (18 28 801.1 thru 18 28 801.19)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation INSTALL SMOKE DETECTORS

1ST FLOOR APARTMENT SMOKE DETECTOR IS MISSING\n\nInstall and maintain approved smoke detectors. (13-196-100 thru 13-196-160) Install a smoke detector in every dwelling unit. Install one on any living level with a habitable room or unenclosed heating plant, on the uppermost ceiling of enclosed porch stairwell, and within 15 feet of every sleeping room. Be sure the detector is at least 4 inches from the wall, 4 to 12 inches from the ceiling, and not above door or window.

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPAIR INTERIOR STAIR SYSTEM

INTERIOR STAIRWELL TREARDS ARE WEAK FROM 1ST TO 3RD FLOOR DECKBOARDS ARE ROTTING ON ALL LEVELS SPINDLES MISSING AT 3RD FLOOR\n\nFailed to maintain interior stairway system in safe condition and sound repair. (13-196-570)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation RAT PROOF OPENINGS

3RD FLOOR APARTMENT FURNACE ROOM HOLES NEAT FLOOR ALLOWING RATS TO ENTER APARTMENT\n\nClose openings around pipes with rat proof materials. (7-28-660)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPAIR EXTERIOR DOOR HARDWARE

EAST ELEVATION FRONT ENTRY ENTRY DOOR DEADBOLT LOCK IS BROKEN; WILL NOT ENGAGE\n\nFailed to maintain exterior door hardware in good condition and repair. (13-196-550(d), 13-196-641)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation INSTALL HEAT APPLNCE FNDATION

3RD FLOOR APARTMENT HOT WATER HEATER SITS DRECTLY ON PLYWOOD FLOOR\n\nInstall foundation under heat producing appliance. (13-180-070)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation STOP LEAKING WATER

3RD FLOOR APARTMENT CEILING LEAKING WATER\n\nStop leaking water. (18-29-102.3)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPAIR PORCH SYSTEM

WEST ELEVATION REAR PORCH BOLTS ARE MISSING AT STRINGERS LEDGER BOARDS AND RAILS BEAMS ARE TOENAILED TO COLUMNS BRACKETS ARE MISSING 3RD FLOOR DECK IS BUCKLING WARDING 2X6 CEILING JOISTS ARE JOISTING; HANDRAIL IS MISSING FROM GRADE TO BASEMENT SCUTLE PANEL IS MISSING AT ROOF HATCH. OBTAIN PERMIT FOR REPAIRS TO REAR PORCH.\n\nFailed to repair or replace defective or missing members of porch system. (13-196-570, 13-196-641)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPAIR / REBUILD SHED

WEST ELEVATION GARAGE CRACK IN EXTERIOR WALL AT SOUTH WEST CORNER SEVERE CRACK DANGEROUS; WALL IS BUCKLING AT NORTH-WEST CORNER; STELL SOUBLE DOORS ARE RUSTING PLYWOOD ON TOP OF ROOF; SHEATING IS ROTTING DEBRIS ) TIRES, LUMBER) ON ROOF EAVES ARE ROTTING. PERMIT REQUIRED FOR REPAIRS OF WREAKAGE OF GARAGE.\n\nFailed to maintain shed in sound condition and repair. (13-196-530, 13-196-641)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPLCE WINDOW PANES, PLEXGLAS

EAST ELEVATION BASEMENT GLASS BLOCK WINDOW PANE IS CRACKED\n\nReplace broken, missing or defective window panes. (13-196-550 A)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPUTTY WINDOW PANES

EAST ELEVATION SOUTH ELEVATION PEELING PAINT ON WINDOW TRIM SOME TRIM IS ROTTING. NORTH ELEVATION WINDOW TRIM IS ROTTING\n\nFailed to retrim or reputty window panes. (13-196-550)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation NO POSTED ADDRESS

BUILDING ADDRESS IS NOT POSTED\n\nPost address of building in conspicuous place on or near entrance with figures at least 3 inches long for residential, or 6 inches long for commercial building. (10-4-050, 10-4-090, 10-4-100)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation POST OWNER/MANAGERS NAME/#

SR 08 00127389 BUILDING OWNERS ID SIGN NOT POSTED\n\nPost name, address, and telephone of owner, owner's agent for managing, controlling or collecting rents, and any other person managing or controlling building conspicuously where accessible or visible to public way. (13-12-030)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPAIR EXTERIOR STAIR

EAST ELEVATION TOP CONCRETE STEP IS CRACKED PEELING PAINT ON LEDGE\n\nFailed to maintain exterior stairways in safe condition and in sound repair. (13-196-570, 13-196-641)

Status last updated on Apartable at 2008-03-20 00:00:00 UTC.
Violation REPAIR COPING

NORTH ELEVATION: PEELING PAINT ON WINDOW SILLS\n\nFailed to maintain roof coping in good repair and free from cracks defects. (13-196-530, 13-196-530(c) and 13-196-641)

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation REPAIR FENCE

SOUTH ELEVATION: TOP AND BOTTOM RAIL IS MISSING; FENCE IS LEANING, LOOSE\n\nFailed to maintain fence in good condition and repair. (7-28-060, 13-196-630, 13-196-641)

Status last updated on Apartable at 2008-07-10 00:00:00 UTC.
Violation INSTALL DOOR VIEWING DEVICE

INTERIOR: VIEWING DEVICE IS MISSING ON ENTRY DOOR\n\nFailed to install door viewing device at the entrance door of a dwelling unit. (13-164-030)

Status last updated on Apartable at 2008-07-10 00:00:00 UTC.
Violation STOP LEAKING WATER

WEST ELEVATION: WATER IS LEAKING FROM ROOF ONTO 3RD FLOOR DECK\n\nStop leaking water. (18-29-102.3)

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation REPAIR / REBUILD SHED

WEST ELEVATION, GARAGE: STEEL DOUBLE DOORS ARE RUSTING; PLYWOOD ON TOP OF ROOF AS SHEATHING IS ROTTING; DEBRIS (TIRES, LUMBER) ON TOP OF ROOF; EAVES ARE ROTTING; CRACK IN EXTERIOR WALL AT SOUTHWEST CORNER; WALL IS BUCKLING AT NORTHWEST CORNER; OBTAIN PERMIT FOR REPAIRS TO GARAGE\n\nFailed to maintain shed in sound condition and repair. (13-196-530, 13-196-641)

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation REPAIR CORNICE

EAST ELEVATION: PEELING PAINT AT CORNICES\n\nFailed to maintain cornice in good repair and free from cracks and defects. (13-196-530(e), 13-196-641)

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation REPAIR EXTERIOR DOOR SILL

EAST ELEVATION: GAPS AT FRONT DOOR THRESHOLD\n\nFailed to maintain exterior door sill in sound condition and repair. (13-196-550, 13-196-641)

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation REPAIR EXTERIOR STAIR

EAST ELEVATION: PEELING PAINT ON WING WALLS; TOP STEP IS CRACKED\n\nFailed to maintain exterior stairways in safe condition and in sound repair. (13-196-570, 13-196-641)

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation OBSTRUCTIONS IN EXIT WAY

NORTH ELEVATION: REAR GATE IS CHAINED AND PADLOCKED\n\nFailed to remove obstruction from exitway that hampers travel and evacuation. (13-160-070, 13-196-080)

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation REPAIR LINTELS

EAST ELEVATION: LINTELS ARE RUSTING\n\nFailed to maintain lintel in good repair and free from cracks and defects. (13-196-530(e), 13-196-641)

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation SERVICE WALK, PASSAGE, AREAWAY

NORTH ELEVATION: SERVICE WALK IS CRACKED, UNEVEN\n\nFailed to maintain exterior service walks, passage and areaways in clean, sanitary and safe condition. (13-196-630, 13-196-641)

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation REPAIR PORCH SYSTEM

REAR PORCH: PLYWOOD COVERING SIDE OF PORCH IS ROTTING; LEDGER BOARD AND RAILS ARE ATTACHED TO EXTERIOR WALL WITH NAILS ONLY, STRINGERS ARE INADEQUATELY SUPPORTED AT COLUMNS, BEAMS ARE INADEQUATELY CONNECTED TO COLUMNS, 3RD FLOOR DECK IS WARPING, UNDERSIZED 2X6 CEILING JOISTS SPAN OVER 15 FEET AND ARE TWISTING, PEELING PAINT ON ALL LEVELS; OBTAIN PERMIT FOR REPAIRS TO REAR PORCH; HANDRAIL MISSING AT BASEMENT\n\nFailed to repair or replace defective or missing members of porch system. (13-196-570, 13-196-641)

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation INSTALL SMOKE DETECTORS

INTERIOR: SMOKE DETECTOR MISSING IN STAIRWELL\n\nInstall and maintain approved smoke detectors. (13-196-100 thru 13-196-160) Install a smoke detector in every dwelling unit. Install one on any living level with a habitable room or unenclosed heating plant, on the uppermost ceiling of enclosed porch stairwell, and within 15 feet of every sleeping room. Be sure the detector is at least 4 inches from the wall, 4 to 12 inches from the ceiling, and not above door or window.

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation ARRANGE PREMISE INSPECTION

NO RESPONSE-2ND, 3RD FLOOR APARTMENTS; BASEMENT-UNVERIFIED DETECTORS AND OCCUPANCY\n\nArrange for inspection of premises. (13-12-100)

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation INT WALL/CEILING CHIP PLASTER

INTERIOR: PLASTER IS FALLING AT STAIR SOFFITS; GAPS BETWEEN DRYWALL AND STAIR STRINGER\n\nFailed to maintain interior ceilings and walls reasonably smooth, clean and tight and free from chipped or loose plaster or structural material. (13-196-540(d) and (e))

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation REPAIR INTERIOR STAIR SYSTEM

INTERIOR STAIRWELL: STAIRS ARE LEANING AND SEPARATING FROM STRINGER; TREADS ARE WEAK FROM 1ST TO 3RD FLOOR; HANDRAIL IS MISSING DECKBOARDS ARE ROTTING\n\nFailed to maintain interior stairway system in safe condition and sound repair. (13-196-570)

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation REPUTTY WINDOW PANES

EAST ELEVATION: PEELING PAINT ON WINDOW TRIM; SOME TRIM IS ROTTING; NORTH ELEVATION: WINDOW TRIM IS ROTTING; SOUTH ELEVATION, ALSO\n\nFailed to retrim or reputty window panes. (13-196-550)

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation NO POSTED ADDRESS

BUILDING: ADDRESS IS NOT POSTED\n\nPost address of building in conspicuous place on or near entrance with figures at least 3 inches long for residential, or 6 inches long for commercial building. (10-4-050, 10-4-090, 10-4-100)

Status last updated on Apartable at 2007-05-15 00:00:00 UTC.
Violation POST OWNER/MANAGERS NAME/#

(SR#07-00612548) BUILDING: OWNER'S ID SIGN NOT POSTED\n\nPost name, address, and telephone of owner, owner's agent for managing, controlling or collecting rents, and any other person managing or controlling building conspicuously where accessible or visible to public way. (13-12-030)

Status last updated on Apartable at 2008-07-10 00:00:00 UTC.

Note: past or pending litigation isn't necessarily indicative of a serious problem with a building or landlord.

Information concerning this building, including complaints, violations and litigation actions, were obtained from various public records. The information is presented for informational and educational purposes only, and Apartable makes no guarantees or warranties as to the accuracy or reliablity of such information or its fitness for a particular purpose.

Listings in North Lawndale

Write a Review Have you lived at 1344 S Kolin Ave? Tell our community about your experience.

Reviews of 1344 S Kolin Ave

based on 0 total ratings

No reviews of 1344 S Kolin Ave yet. Be the first to write one!

Contact an Agent

This property isn't on the market right now, but contact an agent to learn more about it and similar properties in the area.